Vertical Laminar Air Flow System
Vertical Laminar Air Flow System Specification
- Control Type
- Manual / Digital (optional)
- Temperature Resistance
- Not designed for high temperature applications
- Power Supply
- Single Phase
- Accuracy
- Cleanliness up to Class 100 (ISO 5)
- Glass Type
- Front glass viewing panel (tempered glass)
- Speed Range
- 0.30.5 m/s (air flow velocity)
- Shape
- Rectangular
- Features
- High efficiency HEPA filter, low noise operation, UV lamp, energy efficient, ergonomic design
- Display Type
- LED / LCD (optional)
- Type
- Vertical Laminar Air Flow System
- Dimension (L*W*H)
- 900 x 600 x 900 mm (custom sizes available)
- Equipment Type
- Clean Air Equipment
- Equipment Materials
- Mild steel with powder coating / Stainless steel (SS 304/316 optional)
- Power
- 230V AC, 50Hz
- Voltage
- 220-240V
- Material
- Stainless Steel / Mild Steel
- Application
- Microbiology, laboratories, pharmaceutical industry, hospitals, research centers
- Capacity (Ltr)
- 60-120 L
Vertical Laminar Air Flow System Trade Information
- Minimum Order Quantity
- 1 Unit
- Supply Ability
- 10 Units, , Per Week
- Delivery Time
- 1 Week
About Vertical Laminar Air Flow System
Superior Filtration Performance
Equipped with pre-filters rated at 95% efficiency for particles 5 microns and HEPA filters offering 99.97% efficiency for 0.3 micron particles, this system ensures highly purified airflow, maintaining Class 100/ISO 5 cleanliness in accordance with US Federal Standard 209E/ISO 14644-1.
Ergonomic and User-Friendly Design
A work table height of 750-900 mm provides optimal comfort for users. The seamless, rectangular construction allows effortless cleaning, while optional manual or digital controls and LED/LCD displays enhance operational convenience and monitoring.
Safety and Flexibility Features
The unit includes a germicidal UV-C lamp for sterilization and a tempered glass front panel for visibility and safety. Heavy-duty lockable caster wheels enable easy movement and secure positioning, making this system ideal for dynamic laboratory environments. Custom sizes are also available to match specific needs.
FAQ's of Vertical Laminar Air Flow System:
Q: How does the Vertical Laminar Air Flow System maintain air cleanliness in the workspace?
A: The system generates a uniform vertical downward flow of filtered air, passing through pre-filters and high-efficiency HEPA filters. This setup removes particles down to 0.3 microns with 99.97% efficiency, ensuring Class 100/ISO 5 air purity, ideal for sensitive lab processes.Q: What are the main benefits of using this laminar flow system in a laboratory?
A: Benefits include a contaminant-free working area, ergonomic table height for long-duration comfort, seamless interior for easy cleaning, low operation noise (<65 dB), integrated illumination, and optional digital controls for greater accuracy and convenience.Q: Where can this Vertical Laminar Air Flow System be installed?
A: It is suitable for installation in laboratories, research centers, hospitals, pharmaceutical industries, and microbiology environments where a high level of air cleanliness and protection against particulate contamination is necessary.Q: When should the UV-C lamp be used in the operation process?
A: The germicidal UV-C lamp should be activated after cleaning and before commencing sensitive work to sterilize the workspace, minimizing microbial contamination and ensuring a safe environment for samples and operators.Q: How is the air flow velocity controlled and monitored?
A: The air flow velocity, adjustable between 0.3-0.5 m/s, can be set via manual or digital control interfaces. A LED or LCD display (optional) allows real-time monitoring for precise air flow management during procedures.Q: What construction materials are available for the system?
A: Options include mild steel with powder coating or stainless steel (SS 304/316), providing durability, corrosion resistance, and compatibility with varied laboratory requirements. Custom dimensions are available to suit specific workspace needs.Q: What is the process for moving or repositioning the system safely?
A: The unit is fitted with heavy-duty, lockable caster wheels. To move the system, ensure all equipment is secure, unlock the wheels, and carefully transport the unit to the desired location. Once positioned, lock the wheels to maintain stability during operation.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Laboratory Equipment Category
Semi Auto Chemistry Analyzer
Price Range 50000.00 - 500000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Material : High Quality Plastic
Shape : Rectangular
Features : User friendly, Large onboard memory, Multilanguage software, QC program, Printer included
Display Type : 7 Large LCD Touch Screen
Water Still Distillation Unit
Price Range 50000.00 - 500000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Material : Highgrade Borosilicate Glass & Stainless Steel
Shape : Rectangular
Features : Corrosion Resistant, Easy to Clean, Safety CutOff
Display Type : Analog
Horizontal Laminar Air Flow System
Price Range 50000.00 - 500000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Material : Stainless Steel/ Mild Steel with Powder Coating
Shape : Rectangular
Features : HEPA Filter (99.97% efficiency for 0.3 particles), Prefilter, UV Germicidal Lamp, Low Noise, VibrationFree Operation, Energy Efficient
Display Type : Digital Display / LED Indication
Universal Hand Refractometer
Price Range 50000.00 - 500000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Material : Aluminum and glass
Shape : Handheld cylindrical
Features : Portable, easy to use, durable, automatic temperature compensation
Display Type : Analog scale
![]() |